   Author  Topic: AC Blower full on all the time  (Read 377 times)
Pianoman
Full Member
***



24v Ultima Saloon & 2.0 16v Ultima Estate

   
View Profile Email

Posts: 246
AC Blower full on all the time
« on: Apr 24th, 2019, 9:14pm »
Quote Quote Modify Modify

The blower is full on all the times even in the off position. Error code shows 02. I did a reset but it made no difference. Is there anything to try other than replaing things?
 
Thanks
Tony
IP Logged
Tompion
Administrator
*****




1997 2.3 Ultima estate.

   
View Profile

Posts: 2918
Re: AC Blower full on all the time
« Reply #1 on: Apr 24th, 2019, 10:20pm »
Quote Quote Modify Modify

If you have other faults like no interior lights & instrument reset (needles flick round) fuse 17.
 
02 is Blower switch or air distribution switch defective but these descriptions can be deceptive. It could just be the ribbon cable behind the heater control panel not properly latched.
IP Logged

ABS multiplug wheel sensor pins MK IV or MK 20
Pianoman
Full Member
***



24v Ultima Saloon & 2.0 16v Ultima Estate

   
View Profile Email

Posts: 246
Re: AC Blower full on all the time
« Reply #2 on: Apr 27th, 2019, 9:35pm »
Quote Quote Modify Modify

Thanks, the only other fault is that the brake lights are always on but very dim. The fusebox looks dry
 
Tony
IP Logged