Heater blower running all the time.
« on: May 7th, 2004, 9:38pm »
Quote Quote Modify Modify

Hi, Im running a 97 2.0 ultima and have a small prob with the heater blower, basically it's running at max all the time reguardless of the control knob position. I have tried reseting the climate control but this has had not effect, anybody seen this before or knows how to help.
 
Cheers Rog.
IP Logged
ren
Full Member
***



95 N 2.9 24v Cossie Estate

   
View Profile

Posts: 480
Re: Heater blower running all the time.
« Reply #1 on: May 7th, 2004, 11:06pm »
Quote Quote Modify Modify

HI
 look at page 7, ben patricks post same prob
 read the replys  
 or look in the main menu under h b c faults
 
 h t h    
 
  ren
IP Logged
Roger_Chatfield
Newbie
*



I love YaBB 1G - SP1!

   
View Profile

Posts: 2
Re: Heater blower running all the time.
« Reply #2 on: May 7th, 2004, 11:19pm »
Quote Quote Modify Modify

Nice one, now where do I find the HBC.
 
Rog.
IP Logged
ren
Full Member
***



95 N 2.9 24v Cossie Estate

   
View Profile

Posts: 480
Re: Heater blower running all the time.
« Reply #3 on: May 7th, 2004, 11:32pm »
Quote Quote Modify Modify

Hi Rog
 
  lift the bonnett,  near to the windscreen
  in the centre is a black box  depends on
  what type fitted  either one with 3 wire  
   connections sticking out or one with a  
  cover if its this lift the cover remove the 2 screws
  and lift out the h b c  
  without the cover remove the 3 connections  
  remove the 2 screws and lift out at an angle the h b c
     
  h t h
   ren
IP Logged
admin
Administrator
*****



The Big Boss

   
View Profile

Posts: 1410
Re: Heater blower running all the time.
« Reply #4 on: May 7th, 2004, 11:42pm »
Quote Quote Modify Modify

Hi Roger,
 
its all happeneded before and all the ansers are on my ac pages at http://www.fordscorpio.co.uk/acindex.htm
 
the hbc is the achilies heel of the cc system but is a doddle to replace with the new modified version.
 