   Author  Topic: water leek near thermostat housing 2.3  (Read 631 times)
scorpio197
Full Member
***



FORD = Fix Or Repair Daily or Found On Rubish Dump

    sdavid376
View Profile

Posts: 128
water leek near thermostat housing 2.3
« on: Aug 18th, 2006, 7:25pm »
Quote Quote Modify Modify

Hello folks ,my pride and joy has sprung a water leek near the thermostat housing ,it seems to be part of the inlet manifold .Does this mean I need a new inlet manifold or is there another way around this .A friend of mine said maybe you could cut away the housing part and fit a free standing thermostat housing so its not part of the manifold ,I am no mechanic so can anyone out there help ...regards david
IP Logged
Simmo
Administrator
*****



I'm an OAP !

   
View Profile

Posts: 5508
Re: water leek near thermostat housing 2.3
« Reply #1 on: Aug 18th, 2006, 7:43pm »
Quote Quote Modify Modify

David, I think you will find that this problem has been overcome by the use of a 'plastic metal' type compound. Hopefully someone will be along shortly to advise further.
IP Logged

Now I'm an OAP
scorpio197
Full Member
***



FORD = Fix Or Repair Daily or Found On Rubish Dump

    sdavid376
View Profile

Posts: 128
Re: water leek near thermostat housing 2.3
« Reply #2 on: Aug 18th, 2006, 7:55pm »
Quote Quote Modify Modify

Thanks Simmo ,I have been looking at some of the old postings for the last few months ,it seems a common problem ,but most time linked to a blown head gasket  Embarassed  Embarassed
IP Logged
Simmo
Administrator
*****



I'm an OAP !

   
View Profile

Posts: 5508
Re: water leek near thermostat housing 2.3
« Reply #3 on: Aug 18th, 2006, 8:00pm »
Quote Quote Modify Modify

Have you read this one  http://www.fordscorpio.co.uk/cgi-bin/yabb/YaBB.pl?board=Problems;action= display;num=1145264397;start=2#2. See reply re 'quick steel'?.
IP Logged

Now I'm an OAP
Simmo
Administrator
*****



I'm an OAP !

   
View Profile

Posts: 5508
Re: water leek near thermostat housing 2.3
« Reply #4 on: Aug 18th, 2006, 8:02pm »
Quote Quote Modify Modify

Try this site http://www.vintagetractorspares.co.uk/Accessories/Pages/new_page_1.htm.
IP Logged

Now I'm an OAP
solarpanel
Full Member
***



I love YaBB 1G - SP1!

   
View Profile

Posts: 551
Re: water leek near thermostat housing 2.3
« Reply #5 on: Aug 18th, 2006, 8:03pm »
Quote Quote Modify Modify

if its leaking it time for new one asap,you cant bodge it because of the 2 other sensors in the manifold,ford want £200 plus for new manifold ouch.try ebay
IP Logged
scorpio_man
Administrator
*****




Ford Kuga awd

   
View Profile Email

Posts: 5654
Re: water leek near thermostat housing 2.3
« Reply #6 on: Aug 19th, 2006, 12:21pm »
Quote Quote Modify Modify

hi there
 
depending on the size/ location of the crack, you can use 'quick steel' to fix it. you might need to remove it from the car (you'd need to if replacng, anyway).
 
i ripped the brass nut from the plastic manifold (temp sensor) from mine while changing it and fixed it in place with quick steel. that was a year ago (15k miles), and no issue.  
 
best to try first as new one are expensive and rare. follow the instruction carefully for best results.
 
hth
IP Logged
RichardMS
Full Member
***




More mods coming soon !

   
View Profile Email

Posts: 434
Re: water leek near thermostat housing 2.3
« Reply #7 on: Aug 19th, 2006, 6:20pm »
Quote Quote Modify Modify

I bet the leak is on the seam, A weak point where they all appear to go.
I paid £230 for one.
IP Logged

scorpio197
Full Member
***



FORD = Fix Or Repair Daily or Found On Rubish Dump

    sdavid376
View Profile

Posts: 128
Re: water leek near thermostat housing 2.3
« Reply #8 on: Aug 19th, 2006, 8:31pm »
Quote Quote Modify Modify

correct the leek is on the seam ,FMD quoted me £180 + vat and £165 +vat to put it on .The worst thing is that the scorp was going in for a paint job next week ,that will have to wait a week or so now .
IP Logged
RichardMS
Full Member
***




More mods coming soon !

   
View Profile Email

Posts: 434
Re: water leek near thermostat housing 2.3
« Reply #9 on: Aug 19th, 2006, 9:01pm »
Quote Quote Modify Modify

Shocked How much to fit it Shocked
I'll put it for £100 for you Grin Wink
IP Logged

scorpio197
Full Member
***



FORD = Fix Or Repair Daily or Found On Rubish Dump

    sdavid376
View Profile

Posts: 128
Re: water leek near thermostat housing 2.3
« Reply #10 on: Aug 20th, 2006, 7:22am »
Quote Quote Modify Modify

thanks for the offer ,but you are to far away for me to take you up on your offer.I was going to do it myself but after looking at it I decided to leave it to the FMD .If they sod it up they can put it right under warrenty . Grin
IP Logged
scorpio197
Full Member
***



FORD = Fix Or Repair Daily or Found On Rubish Dump

    sdavid376
View Profile

Posts: 128
Re: water leek near thermostat housing 2.3
« Reply #11 on: Aug 30th, 2006, 9:01pm »
Quote Quote Modify Modify

Hello folks ,just an update on the water leak . My FMD fitted a new inlet manifold .The mechanic broke off an injector ,so I had to wait until the next day to get my scorp back.When I got to the FMD I was greeted by the service manager who said :its all fixed injector replaced :but its running very lumpy .....Huh what do you mean lumpy I said ,it was ok when I left it with you .He said come and have a look so I did .theres my scorp up on the ramp we go underneath the engine running real bad .He sprays brake cleaner up at the cat for a few seconds it runs smooth and says your cats gone .to cut a long story short I spent all day to find some one with a cat to fit .and when they took of the heat sheilds there was a nice new looking crack in the middle of the manifold .so one fixed one cracked and only cost me 400 quid ..question to all you mechanics out there ,if the mechanic broke of an injector and tried to start it ,would it flood the system with fuel and could this on ignition be enough to crack the exhaust manifold and would neat fuel damage the cat HuhHuh? I WILL NEVER GO TO AN FMD AGAIN
IP Logged
Matt
Senior Member
****




Manual'd and a 4.0 in the making

   
View Profile Email

Posts: 2816
Re: water leek near thermostat housing 2.3
« Reply #12 on: Aug 30th, 2006, 9:06pm »
Quote Quote Modify Modify

hi mate
 
i'd say it's likely, im sure there is something on the main page, possible the fault finder section, about unburnt fule destroying cats, making them glow bright red...
IP Logged


FDS2000 Scans - Birmingham
Simmo
Administrator
*****



I'm an OAP !

   
View Profile

Posts: 5508
Re: water leek near thermostat housing 2.3
« Reply #13 on: Aug 30th, 2006, 9:12pm »
Quote Quote Modify Modify

Matt. I think what you are referring to isHERE.
IP Logged

Now I'm an OAP
scorpio197
Full Member
***



FORD = Fix Or Repair Daily or Found On Rubish Dump

    sdavid376
View Profile

Posts: 128
Re: water leek near thermostat housing 2.3
« Reply #14 on: Aug 30th, 2006, 9:21pm »
Quote Quote Modify Modify

so I am on the right track ,I am going to complain to the FMD in the morning ,I will let you know how I get on ,thanks folks
IP Logged
Matt
Senior Member
****




Manual'd and a 4.0 in the making

   
View Profile Email

Posts: 2816
Re: water leek near thermostat housing 2.3
« Reply #15 on: Aug 30th, 2006, 9:31pm »
Quote Quote Modify Modify

Simmo,
 
it's likely that it's on that page, but i seem to remember a bit more of a lenghty write up, i'll have to sit down and read the main site again !
 
but reading bit so far, it is quite possible that unburnt fule has entered the cat, destroying it  Sad, but thats unlikely to be the cause of the cracked manifold, but isnt it a common problem of the 2.3's? i know my estate had a cracked exhaust manifold, but a 2.0 one will fit if ur stuck
 
have you had the head checked over, i know that when the plastic inlet cracks, most of the 2.3's ive seen also then have cracked heads (between cylinders 2 and 3)
 
i put a pic on an earlier topic
 
http://www.fordscorpio.co.uk/cgi-bin/yabb/YaBB.pl?board=Problems;action= display;num=1153553673
IP Logged


FDS2000 Scans - Birmingham
Simmo
Administrator
*****



I'm an OAP !

   
View Profile

Posts: 5508
Re: water leek near thermostat housing 2.3
« Reply #16 on: Aug 31st, 2006, 8:37am »
Quote Quote Modify Modify

Scorpio 197, Matt has read the link I put up but thinks there may be more info. If you read the link it would seem that may be a 'scan' would indicate a fault which could help your case. As for the exhaust manifold they certainly have a tendency to crack as indeed mine did, 2ltr 16v, and frankly I did not know. It was found when the clutch went.
IP Logged

Now I'm an OAP
Pages: 1  Reply Reply Send Topic Send Topic Print Print

« Previous topic | Next topic »

Ford Scorpio Forum » Powered by YaBB 1 Gold - SP 1.3.1!
YaBB © 2000-2003. All Rights Reserved.