Air-Con freezing up again, need to isolate mod
« on: Feb 14th, 2007, 3:59pm »
Quote Quote Modify Modify

Dear all
 
My air-con seems to be running until it freezes every time it is engaged.  
 
Now as my system is modded I want to disconnect the mod first to rule that out, but I don't want to uninstall the mod because that may not be the problem.  
 
 Because (according to the CC Mod page) the switch is on a parallel circuit to the main unit, would it be sufficient to simply cut one of the switch's wires at the thingypit end to completely disconnect the mod?  
 
(That way I would be able to easily reconnect it if it turns out that the problem is elsewhere.)  
 
Would that work?  
 
Cheers
 
Paul
 
IP Logged
Daven
Senior Member
****




I'm a cheeky Boy! (Simmos fan club)

   
View Profile WWW

Posts: 1117
Re: Air-Con freezing up again, need to isolate mod
« Reply #1 on: Feb 14th, 2007, 4:26pm »
Quote Quote Modify Modify

on Feb 14th, 2007, 3:59pm, Penguin wrote:

 Because (according to the CC Mod page) the switch is on a parallel circuit to the main unit, would it be sufficient to simply cut one of the switch's wires at the thingypit end to completely disconnect the mod?  
 

 
Yes - the switch's first connection 'off' should make no circuit in the loop so the system defaults back as if no switch is installed - you could completely disconnect the switch and test it with a simple battery and bulb - if you need any help - PM me!
 
Dave
IP Logged
TaperOne
Junior Member
**



135k 98 2.3 Ultima Estate

   
View Profile Email

Posts: 89
Re: Air-Con freezing up again, need to isolate mod
« Reply #2 on: Feb 14th, 2007, 4:26pm »
Quote Quote Modify Modify

Hi Paul,
 
when I disconnected my Mod in 2005, thats pretty much all I did. In fact, I just removed the Mod from the connectors I installed in the coin box and left it at that. Its still in the coin box. As you said, the wires are in parallel. Just make sure you insulate the cut end.
 
HTH
 
Cheers
 
Pete H
IP Logged
Penguin
Full Member
***



Scorpio Owner 12/05 - 7/07

   
View Profile

Posts: 188
Re: Air-Con freezing up again, need to isolate mod
« Reply #3 on: Feb 14th, 2007, 4:31pm »
Quote Quote Modify Modify

Thanks, I'll do that. I reckon it's probably not the mod (which is why I don't want to uninstall it completely until I've checked). I'll see how it goes.  
 
Cheers
 
Penguin
 
PS - If I spelt the word as cackpit instead would it get through?  Cheesy
IP Logged
Neil W
Full Member
***





   
View Profile

Posts: 148
Re: Air-Con freezing up again, need to isolate mod
« Reply #4 on: Feb 14th, 2007, 5:55pm »
Quote Quote Modify Modify

I also had my CC freezing up after installing the mod, even when it was in the "off" position. Later on I found the thermister was faulty, but after replacing it with a new one, I still got freezing up and the mod wasn't even in the circuit.
 
Further checks revealed that the new thermister probe was not quite straight when I installed it in the box; it is important to be very gentle when fitting it back in as even a tiny mis-alignment will cause freezing of the CC.
 
Cheers,
 
Neil W.
IP Logged

1998 Scorpio Ultima Cosworth facelift saloon, reg S896VOG. Sold Feb 2010. Now own Mercedes-Benz E320 CDi.
Penguin
Full Member
***



Scorpio Owner 12/05 - 7/07

   
View Profile

Posts: 188
Re: Air-Con freezing up again, need to isolate mod
« Reply #5 on: Feb 15th, 2007, 1:55pm »
Quote Quote Modify Modify

Well I disconnected the mod at the thingypit end and the system still ran to freezing.  So thinking the problem was likely to be in the themistor alignment (as mentionned above) I thought it would have to go off to the air-con man.  So I connected the mod back up, ran the car the car and the air-con worked fine.
 
 Shocked
 
I take it, therefore, that something's loose - any clues as to what and if I (not particualrly mechanical) could locate it and fix it myself?  
 
Cheers
 
Penguin
IP Logged
Neil W
Full Member
***





   
View Profile

Posts: 148
Re: Air-Con freezing up again, need to isolate mod
« Reply #6 on: Feb 15th, 2007, 4:20pm »
Quote Quote Modify Modify

Hi,
 
I assume you did not touch the thermister itself during the miracle cure  Grin.
 
All I can suggest is re-check your connections, wires, and the rotary switch used in the modification set-up. Could the switch have a loose connection, perhaps?
 
Alternatively, as the AC is now working correctly, leave everything alone until the fault re-appears  Undecided.
 
Cheers,
 
Neil W.
IP Logged

1998 Scorpio Ultima Cosworth facelift saloon, reg S896VOG. Sold Feb 2010. Now own Mercedes-Benz E320 CDi.
Ultima2300
Full Member
***



RIP Blue 2.3 Ultima / White 2.0 8v Executive

   
View Profile

Posts: 203
Re: Air-Con freezing up again, need to isolate mod
« Reply #7 on: Feb 15th, 2007, 5:22pm »
Quote Quote Modify Modify

Now there's been some serious responses...please can I insert a joke about Penguin freezing?
 