Click to return to main site

Welcome, Guest. Please Login or Register.
Jul 7th, 2024, 7:32pm


Balance: £11.65
Home Home Help Help Search Search Members Members Login Login
Ford Scorpio Forum« No heater fan after water pump changed »
   Ford Scorpio Forum
   General
   Problems
(Moderators: admin, Highlander, scorpio_man, Baz, Simmo)
   No heater fan after water pump changed
« Previous topic | Next topic »
Pages: 1  Reply Reply Send Topic Send Topic Print Print
   Author  Topic: No heater fan after water pump changed  (Read 981 times)
goody
Newbie
*



I'm a YaBB newbie!

   
View Profile

Posts: 7
No heater fan after water pump changed
« on: Feb 14th, 2011, 8:46pm »
Quote Quote Modify Modify

hi all
new to the forum so this is my first thread.
 
have a 95 scorpio cosworth and replaced the leaking water pump. all that side of this is fine but ever since then the interior heater fan/motor does not work on any speed. have checked all the fuse in both fuse boards under the bonnet and ok, completely stripped apart the os fuse board cause i heard they get water ingress but all ok.
it did at first lose all the front lights and would not idle but they have sorted themselfs now.
the engine loom was very brittle but manged to reinsulate all that and seems ok.
i must of disturbed something whilst doing the pump but not sure what.
when you turn on the fan speed switch the air con button illuminates but no fan. on occassions when first starting it the air con compressor cuts in but then soon stops and theres been times when i have jumped in it to move it and the fan has briefly worked but soon stopped.
found that there was some kind of base setting you can do with holding the ac and recirc button but no better.
have powered up te fan moter and that works fine so no fault with that and checked feeds to the resistor pack which has feeds on 3 of the 4 wires and the remaning wire seems to be a earth, dont really understand that.
does anybody know whats going on?
 
any info would be much appreciated
nick
IP Logged
gozz
Senior Member
****



Been around awhile

   
View Profile Email

Posts: 3475
Re: No heater fan after water pump changed
« Reply #1 on: Feb 14th, 2011, 8:53pm »
Quote Quote Modify Modify

Did you have the big plug at the front of the main fusebox off,then refit it one row of pins out of line ?
        GOZZ.
IP Logged
goody
Newbie
*



I'm a YaBB newbie!

   
View Profile

Posts: 7
Re: No heater fan after water pump changed
« Reply #2 on: Feb 14th, 2011, 9:41pm »
Quote Quote Modify Modify

Yes I did have it off, thought it went back on ok. Will have to double check that tomorrow then
IP Logged
Snoopy
Administrator
*****



Very old.BAD tempered and missing friends.

   
View Profile Email

Posts: 6278
Re: No heater fan after water pump changed
« Reply #3 on: Feb 15th, 2011, 9:17am »
Quote Quote Modify Modify

If it went on first time then its not fitted correctly..great care has to be taken to fit the plug correctly otherwise some very strange faults and syptoms appear......
 
IP Logged

HELP the FORUM.Please DONATE
Simmo
Administrator
*****



I'm an OAP !

   
View Profile

Posts: 5508
Re: No heater fan after water pump changed
« Reply #4 on: Feb 15th, 2011, 9:32am »
Quote Quote Modify Modify

The crucial thing with the main fusebox is to ensure that the two pins on the fitting are located fully in the lugs on the side of the box. It can be a fiddle but if they are not located,and held there as the plug is pushed down, it will appear ok BUT will be one row of pins out as Gozz and Snoopy suggest. Do you have any 'odd' light problems that is usually a classic sign.  Smiley
IP Logged

Now I'm an OAP
Tompion
Administrator
*****




1997 2.3 Ultima estate.

   
View Profile

Posts: 2918
Re: No heater fan after water pump changed
« Reply #5 on: Feb 15th, 2011, 10:54am »
Quote Quote Modify Modify

The pictures for fitting the multiplug are here:
http://www.fordscorpio.co.uk/cgi-bin/yabb/YaBB.pl?board=admin;action=dis play;num=1267895931
IP Logged

ABS multiplug wheel sensor pins MK IV or MK 20
goody
Newbie
*



I'm a YaBB newbie!

   
View Profile

Posts: 7
Re: No heater fan after water pump changed
« Reply #6 on: Feb 15th, 2011, 7:08pm »
Quote Quote Modify Modify

Hi again, yeah tried the plug and it's definitely on correctly. I just refitted it the wrong way and the lights didn't work so that's what the problem with the lights and the idle was but all fitted right now but still no heater. Do the control panel/switches ever pack up? I heard that the resistor packs play up, could this be the problem? I've got 3 feeds and a earth to the resistor, is that tight? It doesn't seem to change when you operate the fan switch.
IP Logged
Mike H
Senior Member
****




Renault Clio

   
View Profile WWW Email

Posts: 2594
Re: No heater fan after water pump changed
« Reply #7 on: Feb 15th, 2011, 8:08pm »
Quote Quote Modify Modify

Also, the motor commutator wears out....
IP Logged

Mike H
goody
Newbie
*



I'm a YaBB newbie!

   
View Profile

Posts: 7
Re: No heater fan after water pump changed
« Reply #8 on: Feb 15th, 2011, 9:42pm »
Quote Quote Modify Modify

I powered up the fan motor and it worked ok so I guess that's ok
IP Logged
goody
Newbie
*



I'm a YaBB newbie!

   
View Profile

Posts: 7
Re: No heater fan after water pump changed
« Reply #9 on: Feb 16th, 2011, 7:34am »
Quote Quote Modify Modify

Also where abouts is the climate control unit ecu positioned on the vehicle?
IP Logged
Simmo
Administrator
*****



I'm an OAP !

   
View Profile

Posts: 5508
Re: No heater fan after water pump changed
« Reply #10 on: Feb 16th, 2011, 8:47am »
Quote Quote Modify Modify

The unit is behind the controls. Have a look at This page which may help. You talk about a 'resistor' pack. Do you mean This ?.  If not check out a 'button' on the left of the page for HBC repair.
IP Logged

Now I'm an OAP
Pages: 1  Reply Reply Send Topic Send Topic Print Print

« Previous topic | Next topic »

Ford Scorpio Forum » Powered by YaBB 1 Gold - SP 1.3.1!