Ford Scorpio Forum (https://www.fordscorpio.co.uk/cgi-bin/yabb/YaBB.pl)
General >> Give/Need advice to/from others >> Heater Blower only working full blast
(Message started by: Ranjo on Oct 20th, 2004, 12:47pm)

Title: Heater Blower only working full blast
Post by Ranjo on Oct 20th, 2004, 12:47pm
Hi all on my scorpio ghia the heater blower stopped working on the two slow speeds and would only work on full blast. being a long time ford owner i knew that the resistor had given up the ghost. bought a new one from ford £30. they refused to tell me where it was situated on the car as they are not allowed to give out "technical info" but they could fit it for the price of three hours labour!
A second ford dealer told me that it is located at the top of the blower motor which is situated behind the glove box and would require removal of said glove box, which i did but guess what still no location of resistor.
frustrated and thinking horrible thoughts about all ford staff i lifted the bonnet and just happened to spot the resistor casing situated behind the bulk head and to the left of the battery cover. five minutes later using a single screw driver i had changed the resistor and all is working fine.
the reffitting of the glove box is another story though! hope this helps anyone who encounters this heaster problem this winter.

Title: Re: Heater Blower only working full blast
Post by craig on Oct 20th, 2004, 2:38pm
you did the job in 5 minutes then....
ford wanted 3 hours labour ??? ??? ???
enough said there i think :o :o

Title: Re: Heater Blower only working full blast
Post by remco on Oct 26th, 2004, 10:26am
Don't through the resistor away. Sometimes its possible tot fix them. See on the ather part of the site

Title: Re: Heater Blower only working full blast
Post by Ranjo on Oct 27th, 2004, 12:22pm
Thanks i have checked the old resistor and will try to repair it

Title: Re: Heater Blower only working full blast
Post by simonmd on Nov 5th, 2004, 2:19am
Yes, common fault on the Mk3 as well that. Can't believe Ford wanted 3 hrs labour!! Was the dealer called 'D Turpin & Son'?  ;)

Title: Re: Heater Blower only working full blast
Post by Ranjo on Nov 28th, 2004, 6:34pm
Since fitting the resistor it has blown again and have now had to shell out for a new switch resistor and blower motor and it has been a b****r to fit the blower motor as have had to strip quite a bit of casing etc also had to re gas the air con but finally all is well!

Title: Re: Heater Blower only working full blast
Post by Kjelle on Feb 16th, 2005, 12:50am
Hi!
I have fixed my fan resistor.
It´s an temperature fuses in the resistor unit, you can buy an new one and fix the unit.
That fuses costs about 15 sw krones it migth be about one pound, the job takes 10 mins to do!
Kjell....

Title: Re: Heater Blower only working full blast
Post by Kjetil S on Jul 7th, 2006, 4:14pm
Just wondering if someone could post a pic of the resistor where it's mounted so I can find it  ;D

Fan setting 1 and 2 has stopped working, so I guess it's the resistor. Thought I would have a look at it before I change mine.

Title: Re: Heater Blower only working full blast
Post by Snoopy on Jul 7th, 2006, 5:07pm
is this what you are looking for Thermal Fuse (http://www.fordscorpio.co.uk/acthermalfuse.htm) ?????

Title: Re: Heater Blower only working full blast
Post by Kjetil S on Jul 7th, 2006, 7:51pm
Probably. Thanks Snoopy!

Slightly small photo though, should have been a "click to enlarge" option  :)

Title: Re: Heater Blower only working full blast
Post by Kjetil S on Jul 7th, 2006, 9:47pm
Found it  :)

The continuity tester on my multi meter gave no beep when I checked the thermal fuse, but had no problems with the three wire resistors. When I checked the thermal fuse with the ohm meter, it gave a reading of approx 96k ohms. I guess a fuse should have A LOT less resistance than that?

Update: Temporarily soldered a short piece of wire in instead of the fuse, and all fan settings work perfectly now. Also ordered two new fuses at the correct rating and will swap the wire for one of them when I get them. (probably monday)

Cost was approx £1.5 a piece. I think this must be the cheapest repair I've done so far  ;D

Title: Re: Heater Blower only working full blast
Post by jonnycab on Jul 8th, 2006, 2:51am
Ranjo wrote:-

"A second ford dealer told me that it is located at the top of the blower motor which is situated behind the glove box and would require removal of said glove box"

That's where it is in the MK1/MK2 Mondeo!!!....just can't get the staff nowadays ::)



Ford Scorpio Forum » Powered by YaBB 1 Gold - SP 1.3.1!