Hi there

I saw a frecvent fault in AC systems is the CC, when turning the blower fan the system kind of stops and then turns on, also AC light goes off and on again. I did a study on mine (had the same problem) and it's seems that the potentiometer on the PCB inside the CC panel is the problem,  beeing a potentiometer in time it's internal contacts lessen and become lose, also it's resistive element get's "scartched".  If anyone has this problem should try first to change that potentiometer (it can be found in any electronic shop). This is also a verry chep way to make youreself a "remanufactured-CC panel".

If you try this beware of the small LCD temepature screens, because they are verry fragile.