Title: Air con. Help! Post by BENZA on Jul 17th, 2009, 4:07pm after first regass air con was back to life but not for long, it just stopped blowing cold air after 3 days. I noticed that receiver/drier had a leak so replaced that one and regassed again, but no different, still no cold air :(. Have checked fuses all ok, indicator on dash lights up green. How to procced to find a fault? thanks |
||
Title: Re: Air con. Help! Post by gozz on Jul 17th, 2009, 4:45pm BENZA. Is the compressor running,if not,test the clutch with a direct feed,if OK check the circuit to it via pressure valve behind rad grille,and de ice probe in offside of evaporator housing,you can unplug both to test before removing them,there is also a relay in the aux fuse box. GOZZ. |
||
Title: Re: Air con. Help! Post by BENZA on Jul 20th, 2009, 8:09pm Thanks GOZZ will look into that next week |
||