Ford Scorpio Forum (https://www.fordscorpio.co.uk/cgi-bin/yabb/YaBB.pl)
General >> Problems >> Ventilation fans running on constant maximum
(Message started by: Geoff_W on Oct 7th, 2010, 9:18pm)

Title: Ventilation fans running on constant maximum
Post by Geoff_W on Oct 7th, 2010, 9:18pm
I have my suspicions that I have a HBC problem but both left and right ventilation fans are running flat out when the ignition is on. CC controls do not change things at all.

I have temporarily solved the problem (fans off and not working) by unplugging the left hand connector to the HBC.

I do not remember fans failing in the on position.

Any thoughts?

Geoff

Title: Re: Ventilation fans running on constant maximum
Post by Cosray on Oct 7th, 2010, 10:03pm
Hi Geoff - you've only  got one ventilator motor for the CC. With CC you you have two flaps for left and right vents + sensors to control their temp.

Either the fanmotor runs or not or erratically in which case you need a new HBC with a long coling fin.

Behind your radiator you've got two fans each or both controlled by a big relay under the headlight and the EEC-V - are they behaving strangely?

Pls clarify -

Ray

Title: Re: Ventilation fans running on constant maximum
Post by Jonnycab on Oct 8th, 2010, 4:30pm
Is the ribbon cable at the rear of the control panel securely in ?....If it's not, then that causes the blower to run at full pelt   :)