Last update:

08/03/2005

  Climate Control Reset

About Us Useful Links Forums Mailing List

 

Up
AC - How it works
A/C Booster Mod
A/C Thermal Fuse
Climate Control
Climate Control Reset
Cleaning the A/C system
Recharging the AC
AC Repairs
AC Electrical
AC Drain Pipes
AC Hi Pressure Pipe
AC Compressor
Test De-ice Switch
Drain holes
Heater Matrix
HBC Fan repair
Pollen Filters
Test the HBC
AC agents
A/C Manual
Heater Manual

 

 

 

   

Checking and Resetting the Scorpio Climate Control

 

There can be confusion between resetting the climate control module and interrogating it. These are the Ford Technical manual instructions for finding a fault code, and for resetting the module when this has been done.

 

First, a diagram of the sensors, actuators and where to find them:

 

 

Installation position of components

1 Heater/air conditioning controls

2. Blower control

3 Air distribution switch

4 LCD display on passenger side

5 Temperature control switch on passenger side

6 Temperature control switch on driver’s side

7 Recirculated air switch

8 Inside temperature sensor

9 Air conditioning switch (ACS)

10 Sun load sensor (SLD)

11 Automatic temperature control module (ATC)

12 Discharge temperature sensor (DCT), mounted in the heater housing

13 Heater blower control module (HBC), mounted on the evaporator housing

14 Outside temperature sensor (OST), mounted on the evaporator housing

 

System Description

In addition to the manual air conditioning components that remain unchanged, the ATC air conditioning

system also has a separate control module. This control module processes signals from various sensors

that have also been fitted additionally. With the help of the recorded data it is able to automatically control the compressor and the blower in order to maintain a steady inside temperature..

 

Self Diagnosis

The automatic temperature control module carries out a self diagnosis of all connected sensors and control elements in approximately four second cycles. The system registers any faults found during this process. If the same fault occurs in eight consecutive test cycles then the fault is recognised as permanent and stored in memory after "KEY OFF". An intermittent fault is also recognised and stored under a special code (see Fault Code List). A permanent fault entry which is recognised after "KEY ON" is indicated for about three seconds by a flashing "88" (up to build month 12.95) on the passenger side of the display unit. The module operates with a substitute value until the fault has been corrected. An intermittent fault is only cleared from memory if it is not recognised for 80 cycles. The unit can be set to diagnostic mode when the blower control is on "OFF" by simultaneously pressing the "Recirculated Air" and "A/C" buttons for about 10 seconds.

 

Fault Memory – Display and Update

1. Run the engine.

2. Simultaneously press the buttons for "Recirculated Air" and "A/C" for about 10 seconds while the blower control is on "OFF".

3. The contents of the fault memory are then displayed, "00" for no faults or for example "07" for a fault code. While the fault is being processed data is constantly extracted from the sensors and the operation of the actuators is checked. 4. Individual fault codes can be displayed by pressing the passenger side temperature control switch. The selected fault code is then displayed constantly.

5. For diagnosis of the speedometer signal refer to the Vehicle Systems Test Manual "Electrical Systems II".

The following distinction is made between permanent and intermittent faults:

1. Permanent Faults

The fault code is displayed constantly. The display remains up until the fault is rectified, either by renewal of parts or through other means. If the module recognises that the fault has been rectified, then depending on the number of faults either a "0" or "00" is displayed.

2. Intermittent Faults

Intermittent faults are caused by for example a loose connection or a broken wire and do not occur all the time. This type of fault is displayed constantly until tests (checking the wires, plugs etc.) can reveal the actual location of the fault. When the fault display mode is exited the intermittent fault memory is automatically cleared.

 

Exit Fault Processing Mode/Clear Fault Memory

Simultaneously press the buttons for "Recirculated Air" and"A/C" for about 10 seconds while the blower

control is on "OFF". The fault memory is cleared and the system undergoes an initialisation process. The

initialisation process resets the system to a defined starting point (actuators are set to end positions etc.), which is necessary for the system to operate correctly.

Fault Code Details

Fault code list – Electronically controlled air conditioning system

Fault

code

Sensor / actuator Cause of fault

Substitute

value

Action
01

Automatic

Temperature

Control (ATC)

a) Value measured by inside

temperature sensor too small

b) Value measured by inside

temperature sensor too large

+24°C

Replace the heater/air

conditioning controls

 

02

c) Blower switch or air

distribution switch defective

 

03

Outside

temperature sensor

(OST)

a) Value measured by sensor too

small

b) Value measured by sensor too

large

 

+10°C

Carry out electrical checks

 

05

Discharge

temperature sensor,

left-hand side

(DCT-LH)

a) Value measured by sensor too

small

b) Value measured by sensor too

large

+30°C Carry out electrical checks
06

Discharge

temperature sensor,

right-hand side

(DCT-RH)

a) Value measured by sensor too

small

b) Value measured by sensor too

large

+30°C Carry out electrical checks
07

Heater blower

motor (HBM)

Heater blower control module

(HBC) defective or not connected

  Carry out electrical checks
08

Battery voltage (at

BATT POS

terminal)

a) Reading too small

b) Reading too large

  Check battery voltage
09

Air temperature

door motor,

left-hand side

(ATD-LH)

a) Open or

short circuit to ground

b) short circuit to POS

c) Control motor defective

  Carry out electrical checks
10

Air temperature

door motor,

right-hand side

(ATD-RH)

a) Open or

short circuit to ground

b) short circuit to POS

c) Control motor defective

  Carry out electrical checks
11

Air distribution

door motor (ADD)

a) Open or

short circuit to ground

b) short circuit to POS

c) Control motor defective

  Carry out electrical checks

 

 

Programming the Control Unit

In order to ensure that the control unit is calibrated properly after either the control unit or the module have been exchanged, the potentiometers need to be adjusted. For correct calibration turn both switches as far left as possible. If the registered values are outside a certain tolerance (incorrect switch setting) fixed internal values are used, as a result of which the system may not operate correctly. The left-hand end positions are stored in memory and used as a point of reference to determine intermediate positions.

 

Procedure

1. Run the engine.

2. Turn the blower switch and the air distribution switch as far left as they will go.

3. Simultaneously press the buttons for "Recirculated Air" and "A/C" for about 10 seconds until the code"00" appears on the passenger side LCD.

4. Select code "50" using the passenger side temperature control switch.

5. Press the "Recirculated Air" button until the code "00" appears.

6. Simultaneously press the buttons for "Recirculated Air" and "A/C" for about 10 seconds until the code "00" appears on the passenger side LCD. After this step the initialisation process is complete and the adjustment is finished.

There have been several TSB’s issued concerning the cc system. TSB 209/1995 talks of  a fault code “03” continually flashing on the display indicating a faulty outside temperature sensor connected to a faulty ac module.

TSB 209/1995

 

Model: Scorpio ’95 with SATC (Semi Automatic Temperature Control) air conditioning (from 9/94 up to and including 9/95; build code RB to SJ)

 

Subject: Fault code 03 flashes continually on the display.

 

Summary

If a concern arises over continual flashing of ’fault code 03’ on the air conditioning system display, then a defective outside temperature sensor connected to a faulty air conditioning module may be the cause. In this case the module and outside temperature sensor must be renewed (see Parts Required). Old parts (Module Part Numbers: 95GG-18C612-CC and -CD; Sensor Part Numbers: 95GW-19E642-AA) must not be installed, and must be scrapped.

 

NOTE: After installation, the new module must be matched with the setting of the ventilation flaps (see Reset above)

 

Parts Required

Description                          Finis Code

Air conditioning module        1 017 462

Outside temperature sensor  1 017 135

 

Labour Time

Renew outside temperature sensor and control device 1,3 hours

 

Repair Codes

Causal Part: 1 017 462

Defect Code: 07

 

NOTE: The above TSB only relates to vehicles with build codes RB to SJ - and where the above work has not already been carried out. Check the outside temperature sensor number and ensure that you have the Old Parts fitted first before taking any action.

Take a look at the principles of air conditioning and how and why the system works here.

diagram by kind permission of Ford (Europe)

 

 

Copyright © 2004 www.fordscorpio.co.uk