Testing The Ford Scorpio 95+ De - Ice Switch
Testing
Connect the De-Ice switch as shown above, using freezer spray, ice water is not
cold enough, spray the probe for 1 second. The contacts should open and be
indicated on the DVM, within
10 seconds they should re-close.
Removal
To change.
Look at the description here about getting at the
thermistor. Remove the 2 vacuum pipes for the re-circ valve.
Unplug the re-circ valve connector and de-ice switch connector. Remove screw
from top of re-circ assy.
Remove re-circ assy. Remove 2 screws from de-ice switch.
Remove thermistor.
Replacement
Reverse the removal procedure